為了更好地使用低溫廢水回收設(shè)備,我們?cè)谑褂迷O(shè)備時(shí)須更加注意正常運(yùn)行。以下是低溫廢水回收設(shè)備的操作注意事項(xiàng),小編為您解答。
In order to better use the low-temperature wastewater recovery equipment, we must pay more attention to normal operation when using the equipment. The following are the precautions for the operation of the low-temperature wastewater recovery equipment, and I will answer them for you.
1、啟動(dòng)低溫廢水回收設(shè)備時(shí)檢查電路、控制柜線路接線是否正確,電壓和電流是否符合要求。
1. When starting the low-temperature wastewater recovery equipment, check whether the circuit and control cabinet wiring are correct, and whether the voltage and current meet the requirements.
2.低溫廢水回收設(shè)備的水泵采用防堵塞撕裂潛水排污泵。兩個(gè)水泵的控制由微型計(jì)算機(jī)通過檢測(cè)污水箱中的液位來完成。當(dāng)液位從低到高達(dá)到工作水位時(shí),啟動(dòng)工作泵。如果液位繼續(xù)上升到警告水位,關(guān)閉工作泵,啟動(dòng)風(fēng)機(jī)時(shí)檢查旋轉(zhuǎn)方向是否正確,避免反轉(zhuǎn)。
2. The water pump of the low-temperature wastewater recovery equipment is a plug and tear resistant submersible sewage pump. The control of the two pumps is completed by the microcomputer through detecting the liquid level in the sewage tank. When the liquid level reaches the working water level from low to high, start the working pump. If the liquid level continues to rise to the warning water level, turn off the working pump, and check whether the rotation direction is correct when starting the fan to avoid reverse rotation.
3.當(dāng)調(diào)節(jié)箱內(nèi)污水較少,且液位低于水泵啟動(dòng)液位時(shí),兩臺(tái)水泵將停止工作。此時(shí),為使低溫廢水回收設(shè)備中的生物膜正常生長(zhǎng),風(fēng)機(jī)將間歇啟動(dòng)10分鐘,自動(dòng)停止運(yùn)行半小時(shí)。
3. When there is less sewage in the regulating tank and the liquid level is lower than the starting liquid level of the water pump, the two water pumps will stop working. At this time, in order to make the biofilm in the low-temperature wastewater recovery equipment grow normally, the fan will start intermittently for 10 minutes and automatically stop running for half an hour.
4.沉淀池排泥控制。電磁閥通過空氣提升污泥或污泥泵提升污泥。排泥周期為8小時(shí),排泥時(shí)間為8分鐘。當(dāng)空氣被提升時(shí),兩個(gè)風(fēng)扇同時(shí)啟動(dòng),以確??諝夤?yīng)。
4. Sludge discharge control of sedimentation tank. The solenoid valve lifts the sludge through air or sludge pump. The sludge discharge cycle is 8 hours, and the sludge discharge time is 8 minutes. When the air is lifted, both fans are started at the same time to ensure the air supply.
5.風(fēng)機(jī)和水泵由自動(dòng)交替運(yùn)行控制,交替切換時(shí)間為4小時(shí)。
5. The fan and water pump are controlled by automatic alternate operation, and the alternate switching time is 4 hours.
6、
低溫廢水回收設(shè)備控制中心微機(jī)柜上按設(shè)計(jì)安排的工作程序一次完成。手動(dòng)控制是通過面板上的按鍵開關(guān),手動(dòng)控制潛水排污泵和風(fēng)機(jī)的開關(guān)。
6. The micro cabinet of the control center of the low-temperature wastewater recovery equipment shall be completed at one time according to the designed working procedure. Manual control is to manually control the switch of submersible sewage pump and fan through the key switch on the panel.
低溫廢水回收設(shè)備的操作注意事項(xiàng)相關(guān)內(nèi)容便是如此了,如果您對(duì)此有什么不了解的地方,歡迎來我們網(wǎng)站
m.cmicroentropy.com咨詢。
This is the case for the operation of low-temperature wastewater recovery equipment. If you have any questions about this, please visit our website at m.cmicroentropy.com.